The DDP600 front-fan series medical grade power supplies are offered with an internal variable speed front-fan for optimal output power and thermal management, and provides a steady 600 W of regulated DC power through the full 85 to 305 VAC input voltage range, all in a 4.2 x 8.1 x 1.6″ (107 x 206 x 41mm) form factor.
-
600 W steady state power with 800 W peak (up to 10s)
-
85 – 305 VAC wide input voltage range
-
24, 28, 36 and 48 VDC output variants
-
94% efficiency rating
-
Parallel & N+1 redundant operation
-
+5V stand-by & 12V auxiliary outputs
-
Low stand-by consumption (< 0.35 W)
-
Input surge current limiting
-
2x MoPP – BF compliant
-
Laboratory equipment
-
Dialysis equipment
-
Ultrasound equipment
-
Aesthetic laser equipment
-
Medical imaging
-
Other medical electronics
Capable of 800 W of peak power for 10 seconds, the DDP600 medical grade front-fan series is very well suited for applications demanding a high start-up current, while allowing for space and cost savings. The front-fanned version has a built in smart cooling solution that adjusts the fan speed to the working conditions, minimizing acoustical noise and air movement.
Exceptionally high reliability is achieved with 94% efficiency for lower heat generation which facilitates better thermal management in space constrained systems.
Macro industries applications
List of models
- Max # Outputs
- 1
- V2 Out (V)
- 12
- I2 Out (A)
- 1
- V3 Out (V)
- 5
- I3 Out (A)
- 1.5
- Efficiency Rating (%)
- 94
- Operating Altitude (m)
- 3000
- Operating temperature range
- -20 to 50°C
- Safety
- UL8750, IEC 60601-01 3rd ed., 2x MoPP, IEC 60950-1, IEC 62368-1
- Max # Outputs
- 1
- V2 Out (V)
- 12
- I2 Out (A)
- 1
- V3 Out (V)
- 5
- I3 Out (A)
- 1.5
- Efficiency Rating (%)
- 94
- Operating Altitude (m)
- 3000
- Operating temperature range
- -20 to 50°C
- Safety
- UL8750, IEC 60601-01 3rd ed., 2x MoPP, IEC 60950-1, IEC 62368-1
- Max # Outputs
- 1
- V2 Out (V)
- 12
- I2 Out (A)
- 1
- V3 Out (V)
- 5
- I3 Out (A)
- 1.5
- Efficiency Rating (%)
- 94
- Operating Altitude (m)
- 3000
- Operating temperature range
- -20 to 50°C
- Safety
- UL8750, IEC 60601-01 3rd ed., 2x MoPP, IEC 60950-1, IEC 62368-1
- Max # Outputs
- 1
- V2 Out (V)
- 12
- I2 Out (A)
- 1
- V3 Out (V)
- 5
- I3 Out (A)
- 1.5
- Efficiency Rating (%)
- 94
- Operating Altitude (m)
- 3000
- Operating temperature range
- -20 to 50°C
- Safety
- UL8750, IEC 60601-01 3rd ed., 2x MoPP, IEC 60950-1, IEC 62368-1