Start / Power Systems / DC Power Systems / OPUS HE OC0864 Wall Cabinet Power System

OC0864 OPUS HE OC0864 Wall Cabinet Power System

The OPUS HE Wall-mount DC Power systems are natural convection cooled, modular wall-mounted charging rectifier systems for industrial market applications. The system is typically charging external bank and providing uninterrupted DC power for critical applications.

  • Modular wall-mount DC power system
  • N+1 redundancy
  • Natural convection cooling – low noise operation
  • Easy installation
  • Standard versions 24, 48, 60, 110, 125, 220 VDC
    6kW (24V 4.5kW) cabinet for 3 rectifiers
    12kW (24V 9kW) cabinet for 6 rectifiers
    Inverter or DC/DC option in 6kW cabinet
  • Battery connection: 1-3 MCB or Switch Fuse
  • Configurable load distribution
  • EMC ratings:
    Cabinet: EN61439-1, EN61439-2
    Rectifiers: EN 61000-6-1 / -2 / -3 / -4 / -5
    EN50121-4 Rail, ETSI EN 300386 (48/60V)
  • Safety ratings:
    Cabinet: EN61439-1, EN61439-2
    Rectifiers: EN 62368-1, EN 50124-1 rail
  • Critical infrastructure
  • Transmission substations
  • Distribution substations
  • Railway signaling and substations
  • Process industries
  • Telecommunications

OPUS HE Wall mountable power systems are an industrial grade solution family that delivers uninterrupted power for whole voltage ranges from 24V to 220VDC. With highly efficient, convection-cooled rectifiers, a state-of-the-art controller, and a highly modular mechanical structure, the OPUS HE Series can be easily configured to meet a multitude of utility, industrial and rail applications.

OPUS HE Wall mount systems come in an IP20 / IP21 enclosure and consist of the MHE rectifiers (up to 6 modules), VIDI+ I/O controller, MCB or switch fuse protection for the battery and MCB protection for the mains. For lead connections there are both bulk screw terminal outputs and a couple of configurable MCBs.

List of models

Model number
Power Out Max (kW)
Module Positions
Input Voltage (VAC)
Input Voltage (VDC)
Output Current Max (A)
Cooling
V1 Out Nom (V)
24
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
24
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
48
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
48
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
60
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
60
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
110
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
110
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
125
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
125
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
1477
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2
V1 Out Nom (V)
1477
Operating temperature range
-25°C to +60°C see derating
IP Rating
IP20 / IP21
Safety
EN61439-1 / EN61439-2

Accessories

OPUS Battery Fuse Box

  • Wall Mountable Fuse Box for Battery Installations
  • Switch Fuse Protection
  • Configurable Fuse Link
  • Up to 125A

OPUS Battery Cabinet For Front Terminal Batteries

  • 4 Battery shelves 320 x 530 x 595 mm
  • User terminals 35 mm (8 pcs)
  • Cable entry from top, neoprene cable glands (optional bottom cable entry)
  • Adjustable legs

OPUS IC Battery Cabinets with Switch Fuse Protection

  • Battery shelves for up to 4 x 48V/190Ah batteries
  • Switch fuse protected battery strings (4 x 125A NH00 – fuse monitoring)
  • Cable entry from top
  • Ventilation output on the top
  • Adjustable legs
  • Strong welded structure
  • Top lifting eyes