Start / Power Systems / DC Power Systems / OPUS HE Cabinet Power Systems

OPUS HE OPUS HE Cabinet Power Systems

OPUS HE DC power systems are configurable and scalable, natural convection cooled, n+1 redundant backup power solutions designed to meet the demands of critical infrastructure applications.

  • Efficiency up to 97%
  • Fan Free – Natural convection cooled
  • Standard output voltages: 24, 48, 60, 110, 125 and 220 VDC
  • Scalable power 1.5 kW – 24 kW, double cabinet up to 48 kW
  • Configurable battery connections:
    1-3 strings
    MCB, MCCB or Switch fuse protection
  • Configurable battery shelves and load distribution modules
  • Cabinet types selectable: Enedo OC or IC or RC Rittal cabinet
  • Height 2m or 1.6m, width 600 mm, depth 600 mm
  • IP class IP20 … IP4x
  • EMC ratings:
    EN 61000-6-1 / -2 / -3 / -4 / -5
    Rectifiers & VIDI2: EN50121-4/-5 Rail, ETSI EN 300386 (48/60V)
  • Safety ratings:
    Cabinet: EN61439-1, EN61439-2
    Rectifiers: EN 62368-1, EN 50124-1 rail
  • Critical infrastructure
  • Transmission substations
  • Distribution substations
  • Railway signaling and substations
  • Process industries
  • Telecommunications
  • Certification CE

OPUS HE power systems are robust backup power systems that deliver from 2 – 24 kW of output power at 48, 60, 110, 125 and 220 VDC, and from 1.5 – 18 kW at 24 VDC output. The cabinets have standard configurations for 3, 6 or 12 MHE rectifier modules, VIDI+ controllers, connections for mains and battery, and load distribution fuses or MCBs. Systems can easily be tailored to match unique application requirements by changing the quantity of rectifiers, battery fuses, battery shelves, load distribution and many other features.

In addition to 12 configurable relay alarms, systems can be remotely monitored via modern communication protocols such as Ethernet TCP/IP, Modbus TCP/IP, SCADA IEC61850, SNMP and RS-232.
OPUS HE power systems deliver up to 97% efficiency, are scalable from 1.5 kW to 24 kW, and are suitable for use in Power transmission substations, Power distribution substations, Railway signaling and substations, Process industries, and Telecommunications.

  • 2 years warranty
  • Natural Convection or Fan

List of models

Model number
Power Out Max (kW)
Input Voltage (VDC)
Output Voltage Range (VDC)
Output Current Min (A)
Output Current Max (A)
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
42
V1 Out Nom (V)
48
V1 Out Max (V)
59
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
42
V1 Out Nom (V)
48
V1 Out Max (V)
59
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1

Accessories

OPUS Battery Fuse Box

  • Wall Mountable Fuse Box for Battery Installations
  • Switch Fuse Protection
  • Configurable Fuse Link
  • Up to 125A

OPUS IC Battery Cabinets with Switch Fuse Protection

  • Battery shelves for up to 4 x 48V/190Ah batteries
  • Switch fuse protected battery strings (4 x 125A NH00 – fuse monitoring)
  • Cable entry from top
  • Ventilation output on the top
  • Adjustable legs
  • Strong welded structure
  • Top lifting eyes

OPUS Battery Cabinet For Front Terminal Batteries

  • 4 Battery shelves 320 x 530 x 595 mm
  • User terminals 35 mm (8 pcs)
  • Cable entry from top, neoprene cable glands (optional bottom cable entry)
  • Adjustable legs